    Take AC voltage, current, and frequency measurements without making contact with the live voltage with T6-600 tester. The 62 Max + infrared thermometer helps you identify areas to be measured and the 1AC-II voltage tester tests for energized circuits. Additionally, this kit is ideal for electricians and HVAC/R technicians.

    • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage
    • Identify areas to be measured and the voltage tester tests for energized circuits

    Fluke T6-600 Electrical Tester

    FunctionRequires test leadsRangeResolutionAccuracy[1]
    FieldSense
    ac voltage true-rms
    No600 V1 V��(3% + 3 counts) 45 Hz - 66 Hz[2] [3]
    FieldSense
    ac current true-rms
    No200.0 A0.1 A��(3% + 3 counts) 45 Hz - 66 Hz
    FieldSense
    frequency (Hz)
    No 1 Hz��(1% + 2 counts)[3]
    Volts ac true-rmsYes600 V1 V��(1.5% + 2 counts) 45 Hz - 66 Hz
    Volts dcYes600 V1 V��(1% + 2 counts)
    ResistanceYes2000 1 ��(1% + 2 counts)
    Safety 600 V CAT III

    Accuracy[1]: �� ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.

    Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.

    Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

    Calibration1-year calibration cycle
    Dimensions61.1 x 259.3 x 43.8 mm
    Jaw opening17.8 mm
    Weight0.35 kg (0.78 lb)
    TemperatureOperating-10 °C to +50 °C (14 °F to 122 °F)
    Storage-30 °C to +60 °C (-22 °F to +140 °F)
    AltitudeOperating2,000 m (6,562 feet)
    Storage10,000 m (32,808 feet)
    Relative Humidity0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
    0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
    0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
    Battery Type and Life2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
    Temperature coefficient0.1 x (specified accuracy) / °C for <18°C or >28 °C
    (< 64.4 °F or > 82.4 °F)
    SafetyIEC/EN 61010-1: Pollution Degree 2
    Electromagnetic EnvironmentIEC/EN 61326-1: Portable