Home
/
FLUKE 1000V Wireless Multimeter & Deluxe Kit FLUFLK3000FC/EDA2
FLUKE 1000V Wireless Multimeter & Deluxe Kit FLUFLK3000FC/EDA2
Quantity
-
Detail
Now compatible with Fluke Connect® Mobile App
Fluke's 3000 FC Series Wireless Multimeter puts wireless test tools, not your body, near live electrical panels. Improve safety and efficiency with this tester.
All the facts, right in the field. The Fluke 3000 FC True-rms Wireless Multimeter with the Fluke Connect app and ShareLive™ video call.
With its precision, reliability and ease of use, the Fluke 3000 FC Wireless Multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600V/ CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to troubleshoot and repair many problems in electrical and electronic systems.
The Fluke 3000 FC gives you True-rms voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 3000 FC provides higher 0.09% basic accuracy, a digital display showing up to three secondary measurements from remote modules, and a bright white backlight.
Work safely near electrical panels while wearing less PPE
The Fluke 3000 FC True-rms Wireless Multimeter and Fluke Connect wireless test tools put tools, not your body, near live electrical panels. It's simple. Just de-energize the cabinet, open the panel while wearing PPE and connect the remote modules, whether they are voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC Wireless Multimeter from a safe distance. You can display the meter measurement, plus readings from up to 3 wireless modules, while reducing the risk of arc flash by separating yourself from hazardous measurement situations.
Better still, the Fluke 3000 FC Series Wireless Multimeter can send measurement data to your smartphone, so you can save and share measurements from the field with your team anytime, from anywhere.
Don't get bogged down while chasing interrelated events
Timing is everything when trying to find the cause of a complex problem. Often you need to make a measurement in one place and see activity on a different part of the system at the same time. We've solved that problem with Fluke Connect - connect your remote modules in one location, then take your measurements up to 20 meters away with the Fluke 3000 FC multimeter. You'll be able to see the interaction between your remote test points on one single screen, in real time. You can even download the data to a PC for further analysis.
Other capabilities of Fluke Connect and the 3000 FC Multimeter.
- Add your laptop and go from logging to analysis and diagnosis.
- Record over time using the Fluke Connect wireless modules and monitor circuit load changes for an hour, a shift or a week.
- Use the Fluke Connect wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data.
- Perform for analysis with your PC and share the results using Fluke Cloud™ storage and ShareLive™ video call. View data or graphs to get input from team members.
Specifications
AC Voltage Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 VAccuracy2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 kHz 2.0% + 3 1. AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.DC Voltage, Continuity, Resistance, Diode Test and Capacitance mV Range / resolution 600.0 mV / 0.1 mV Accuracy 0.09% + 2 V Range / resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 VAccuracy 0.09% + 2
0.15% + 2))) Range / resolution 600 Ω / 1 Ω Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. Ω Range / resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩAccuracy 0.5% + 2
0.5% + 1
1.5% + 3Diode test Range / resolution 2.000 V / 0.001 V Accuracy 1% + 2 µF Range / resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μFAccuracy 1.2% + 2
10% typical1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. AC and DC Current mA AC
(45 Hz to 1 kHz)Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mAAccuracy 1.5% + 3 mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mAAccuracy 0.5% + 3 1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.Frequency Range / resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHzAccuracy1 0.1% + 1 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. Input Characteristics Overload protection 1100 V RMS Input impedance (nominal) > 10 MΩ < 100 pF Common mode rejection ratio
(1 kΩ unbalance)> 120 dB at DC, 50 Hz or 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Overload protection 1100 V RMS Input impedance (nominal) > 10 MΩ < 100 pF Common mode rejection ratio
(1 kΩ unbalance)> 60 dB, DC to 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Overload protection 1100 V RMS Input impedance (nominal) > 10 MΩ < 100 pF Common mode rejection ratio
(1 kΩ unbalance)> 120 dB at DC, 50 Hz or 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Open Circuit Test Voltage Overload protection 1100 V RMS Input impedance (nominal) < 2.7 V DC Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ< 0.7 V DC
< 0.9 V DCTypical short circuit current < 350 mA Overload protection 1100 V RMS Input impedance (nominal) < 2.7 V DC Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ2.000 V DC Typical short circuit current < 1.1 mA mA Function Overload protection Fused, 44/100 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum MIN/MAX Recording Accuracy DC functions ± 12 counts for changes > 350 mS in duration. AC functions ± 40 counts for changes > 900 mS in duration. General Specifications Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate 4/sec Volts, amps, ohms 6000 counts Frequency 10,000 counts Capacitance 1,000 counts Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 250 hours minimum RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20m Obstructed, sheetrock wall Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m Temperature Operating -10°C to 50°C Storage -40°C to 60°C Temperature coefficient 0.1 X (specified accuracy) / °C (< 18°C or > 28°C) Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)Altitude Operating 2,000 m Storage 12,000 m Electromagnetic compatibility
EMI, RFI, EMC, RFEN 61326–1:2006, EN 61326–2–2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLESafety compliance ANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010Certifications CSA, FCC, CE Ingress Protection (IP) rating IP54 Pollution Degree 2 Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight 340 g (12 oz) Warranty Three years Not compatible with Fluke CNX test tools Customer ReviewsNo commentsYou May Also Like