FLUKE CNX 3000 Industrial System FLUFLK3000FCIND
FLUKE CNX 3000 Industrial System FLUFLK3000FCIND
Quantity
-
Detail
The Fluke CNX™ 3000 Industrial System lets you work on electrical panels faster, safer, easier.
Denergize the cabinet, connect the remote modules, close the cabinet and reenergize. The CNX™ 3000 Industrial System displays the readings wirelessly on the CNX multimeter.
Connect the three CNX i3000 iFlex AC Wireless Current Modules to your test points, and view the results from all three phases in 1/3 the time and cost of current test methods. Or connect the CNX v3000 AC Wireless Voltage Module and view both voltage and current measurements simultaneously. You'll get better answers, faster, and spend less time in full PPE.
From short distances, you can even view readings from modules through closed electrical panels. Plus the CNX remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm's way.
The CNX 3000 Industrial System provides measurement of all common electrical parameters.
The CNX 3000 Wireless Multimeter offers:
- True RMS AC and DC voltage measurements to 1000V
- True RMS AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V; CAT IV 600 V; IP54
The CNX i3000 iFlex AC Wireless Current Module offers:
- True RMS AC current measurements to 2500 A
- 3% accuracy
- Memory recording up to 65,000 readings
- iFlex current probe allows you to get into tight, awkward spaces
- Backlit LCD display
- CAT III 1000, CAT IV 600 V, CAT III 1000 V; IP42
The CNX v3000 AC Wireless Voltage Module offers:
- True RMS AC voltage measurements to 1000V
- ��1% accuracy to 500 Hz, �� 2% accuracy to 1 kHz
- Memory recording up to 65,000 readings
- Backlit LCD display
- CAT IV 600 V, CAT III 1000 V; IP42
The CNX wireless system can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.
Specifications:
CNX 3000 Wireless Multimeter
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of �� ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications AC Voltage Range Resolution Accuracy 45 Hz to 500 Hz 500 Hz to 1 kHz 600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V Notes:
AllAC voltage ranges are specified from 1 % of range to 100 % of range.
Crest factor of �� 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
For non-sinusoidal waveforms, add �C(2 % of reading + 2 % full scale) typical, for crest factor up to 3.DC Voltage, Continuity, Resistance, Diode Test and Capacitance Function Range Resolution Accuracy mV 600.0 mV 0.1 mV 0.09 % + 2 V 6.000 V 0.001 V 0.09 % + 2 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 0.15 % + 2 �� 600 �� 1 �� Meter beeps at < 25 ��, beeper detects opens or shorts of 250 ��s or longer. �� 600.0 �� 0.1 �� 0.5 % + 2 6.000 k�� 0.001 k�� 0.5 % + 1 60.00 k�� 0.01 k�� 60.00 k�� 0.1 k�� 600.0 k�� 0.001 M�� 50.00 M�� 0.01 M�� 1.5 % + 3 Diode test 2.000 V 0.001 V 1 % + 2 ��F 1000 nF 1 nF 1.2 % + 2 10.00 ��F 0.01 ��F 100.0 ��F 0.1 ��F 9999 ��F 1 ��F 10 % typical Notes:
In the 9999 ��F range for measurements to 1000 ��F, the measurement accuracy is 1.2 % + 2.AC and DC Current Function Range Resolution Accuracy mA AC
(45 Hz to 1 kHz)60.00 mA 0.01 mA 1.5 % + 3 400.0 mA 0.1 mA mA DC 60.00 mA 0.01 mA 0.5 % + 3 400.0 mA 0.1 mA Notes:
All AC current ranges are specified from 5 % of range to 100 % of range.
Input burden voltage (typical): 400 mA input 2 mV/mA.
400.0 mA accuracy specified up to 600 mA overload.Frequency Range Resolution Accuracy 99.99 Hz 0.01 Hz 0.1 % + 1 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz Notes:
Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.Input Characteristics Function Overload
ProtectionInput Impedance
(nominal)Common Mode Rejection Ratio (1 k�� unbalance) Normal Mode Rejection 1100 V RMS > 10 M�� < 100 pF > 120 dB at DC,
50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz 1100 V RMS > 10 M�� < 100 pF > 60 dB, DC to 60 Hz 1100 V RMS > 10 M�� < 100 pF > 120 dB at DC,
50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz Open circuit test voltage Full scale Typical short circuit current 1100 V RMS < 2.7 V DC To 6 M��:< 0.7 V DC
50 M��:< 0.9 V DC< 350 mA 1100 V RMS < 2.7 V DC To 6 M��:2.000 V DC < 1.1 mA Function Overload Protection Overload mA Fused, 44/100 A,
1000 V FAST Fuse600 mA overload for 2 minutes maximum, 10 minutes rest minimum MIN/MAX Recording Function Accuracy DC functions The specified accuracy of the measurement function �� 12 counts for changes > 350 mS in duration. AC functions The specified accuracy of the measurement function �� 40 counts for changes > 900 mS in duration. General Specifications Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS �� fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 countsBattery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 300 hours minimum Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °CRelative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)Altitude Operating: 2,000 m
Storage: 12,000 mTemperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) Wireless frequency 2.4 GHz ISM Band 20 meter range Size (HxWxL) 4.75 cm x 9.3 cm x 20.7 cm
(1.87 in x 3.68 in x 8.14 in)Weight 340 g (12 oz) Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010Electromagnetic compatibility
EMI, RFI, EMC, RFEN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCSIngress Protection (IP) rating IP54 Notes:
Accuracy is specified as �� ([% of reading] + [number of least significant digits]).
All ranges are autoranging.
Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.Fluke CNX i3000 iFlex AC Wireless Current Module
Specifications Range 2500 A AC Resolution 0.1 A to 999.9, 1A from 1000 to 2500 Accuracy 3 % �� 5 digits Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 Display 3-1/2 digits, LCD w/backlight Log rate/interval 1 sec minimum/adjustable by PC or front panel Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range 20 Meters Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity 90 % at 35 °C
75 % at 40 °C
45 % at 50 °CEMC EN 61326-1:2006 Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002Pollution degree 2 Temperature coefficient Add 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C) Safety rating CAT IV 600 V, CAT III 1000 V Certifications CSA, FCC T68-FWCS IC:6627A-FWCS Ingress Protection (IP) rating IP42 Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) Weight .22 kg (8 oz) Jaw opening 25.4 cm (10 in) coil
Fluke CNX v3000 AC Wireless Voltage ModuleAccuracy is specified as �� ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage Range Resolution Accuracy 45 Hz to 500 Hz 500 Hz to 1 kHz 6.000 V 0.001 V 1.0 % + 3 2.0 % + 3 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V Notes:
All AC voltage ranges are specified from 1 % of range to 100 % of range.
Crest factor of �� 3 at full scale up to 500 V, decreasing linearly to crest factor �� 1.5 at 1000 V.
For non-sinusoidal waveforms, add �C(2 % of reading + 2 % full scale) typical, for crest factor up to 3.General Specifications LCD w/backlight 3 digits, 6000 counts, updates 4/sec Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings Unbound listen interval 5 seconds RF communications 2.4 GHZ ISM Band RF communication range 20 Meters Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C EMC EN 61326-1:2006 Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008Pollution degree 2 Temperature coefficient 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C) Safety rating CAT IV 600 V, CAT III 1000 V Certifications CSA, FCC T68-FWCS IC:6627A-FWCS Ingress Protection (IP) rating IP42 Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) Weight .22 kg (8 oz) -