Home / Electrical Tools / FLUKE Thermometer, Electrical Tester & Voltage Detector Kit FLUT5-600/62/1ACKIT

FLUKE Thermometer, Electrical Tester & Voltage Detector Kit FLUT5-600/62/1ACKIT

Quantity
ADD TO CART
BUY IT NOW
  • Detail

    This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.

    Fluke T5 Voltage, Continuity and Current Testers.

    • Automatically measures volts AC and volts DC with precise digital resolution.
    • Displays resistance to 1000 ��.
    • Easy and accurate OpenJaw™ current measurement.
    • Continuity beeper.
    • Rugged enough to withstand a 10 ft (3 m) drop.
    • 600 V model.
    • Auto off mode to conserve battery life.
    • AC current.
    • Display hold.
    • All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.

    Fluke 62 MAX+. Small in size. Big on toughness.

    • Dust and water-resistant: IP54 rated.
    • Rugged: 3 m (9.8 ft) drop tested.
    • Ergonomically designed: Completely redesigned for a more natural hand fit.
    • Distance to spot: 12:1.
    • Dual lasers: Identifies area to be measured.
    • Large, backlit display: Makes data easier to read, even in dark areas.
    • C115 Deluxe soft carrying case with shoulder strap.

    Fluke T5-600 Voltage, Continuity and Current Tester

    Specifications
    Jaw opening12.9 mm (0.5 in)
    Max wire size1/0 THHN cable
    Current range AC rms0 to 100.0 A
    Accuracy AC current (50/60 Hz)3% �� 3 counts
    AC ResponseAveraging
    Voltage range AC0 to 600 V
    Accuracy AC voltage1.5% �� 2 counts
    Voltage range DC0 to 600 V
    Accuracy DC voltage1% �� 1 count
    Resistance range0 to 1000 ��
    Continuity beeper thresholdOn at < 25 ��, off at > 400 ��
    Volts indicator LED thresholdGuaranteed on by 30 V AC
    Environmental Specifications
    Operating temperature-10°C to 50°C
    Storage temperature-30°C to 60°C
    Humidity (without condensation)0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C);
    0% to 45% (40°C to 50°C)
    Dust/water resistanceYes
    Operating altitude2000 meters max
    Temperature coefficient0.1 x (specified accuracy)/°C (< 18°C or > 28°C)
    Safety Specifications
    Measurement CategoryIEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac
    Agency approvalsCSA, TUV
    Maximum voltage600 V between any terminal and earth ground
    Mechanical and General Specifications
    Size30.5 x 51 x 203 mm
    Weight300 g
    WarrantyTwo-years
    Battery life200 hour zinc chloride, 400 hour alkaline
    Battery type2 x AA
    Low battery indicatorYes
    Current sensor opening12.9 mm
    Calibration cycle1 year
    Test leadsTypeHeavy duty, flexible leads rated for 1000 V use.
    Field replaceable leads terminate in male shrouded banana plugs
    ProbesOne red, one black.
    Detachable Slim-Reach™ probe tips
    StylesTP1 Slim Reach™ test brobes
    Safety Specifications
    SafetyCAT IV 600 V, CAT III, 1000 V
    Maximum voltage1000 V AC rms from earth to ground, in compliance with EN61010


    Fluke 62 MAX+ Infrared Thermometer

    Specifications
    Temperature range-30°C to 650°C (-22°F to 1202°F)
    Accuracy��1.0°C or ��1.0% of reading, whichever is greater
    -10°C to 0°C: ��2.0
    -30°C to -10°C: ��3.0
    Response time (95%)< 300 ms (95% of reading)
    Spectral response8 to 14 microns
    Emissivity0.10 to 1.00
    Optical resolution12:1 (calculated at 90% energy)
    Display resolution0.1°C (0.2°F)
    Repeatability of readings��0.5% of reading or < ��0.5°C (1°F), whichever is greater
    PowerAA battery
    Battery life8 hours with laser and backlight on
    Physical Specifications
    Weight255 g (8.99 oz)
    Size175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
    Operating temperature0°C to 50°C (32°F to 122°F)
    Storage temperature-20°C to 60°C (-4°F to 140°F), (without battery)
    Operating humidity10% to 90% RH non-condensing at 30°C (86°F)
    Operating altitude2000 meters above mean sea level
    Storage altitude12,000 meters above mean sea level
    IP ratingIP 54 per IEC 60529
    Drop test3 meters
    Vibration and shockIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
    EMCEN 61326-1:2006 EN 61326-2:2006
    Standards and agency approvalComplianceEN/IEC 61010-1: 2001
    Laser safetyFDA and EN 60825-1 Class II
  • Customer Reviews
    No comments