    Now compatible with Fluke Connect® Mobile App

    Fluke's 3000 FC Series Wireless Multimeter puts wireless test tools, not your body, near live electrical panels. Improve safety and efficiency with this tester.

    All the facts, right in the field. The Fluke 3000 FC True-rms Wireless Multimeter with the Fluke Connect app and ShareLive™ video call.

    With its precision, reliability and ease of use, the Fluke 3000 FC Wireless Multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600V/ CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to troubleshoot and repair many problems in electrical and electronic systems.

    The Fluke 3000 FC gives you True-rms voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 3000 FC provides higher 0.09% basic accuracy, a digital display showing up to three secondary measurements from remote modules, and a bright white backlight.

    Work safely near electrical panels while wearing less PPE

    The Fluke 3000 FC True-rms Wireless Multimeter and Fluke Connect wireless test tools put tools, not your body, near live electrical panels. It's simple. Just de-energize the cabinet, open the panel while wearing PPE and connect the remote modules, whether they are voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC Wireless Multimeter from a safe distance. You can display the meter measurement, plus readings from up to 3 wireless modules, while reducing the risk of arc flash by separating yourself from hazardous measurement situations.

    Better still, the Fluke 3000 FC Series Wireless Multimeter can send measurement data to your smartphone, so you can save and share measurements from the field with your team anytime, from anywhere.

    Don't get bogged down while chasing interrelated events

    Timing is everything when trying to find the cause of a complex problem. Often you need to make a measurement in one place and see activity on a different part of the system at the same time. We've solved that problem with Fluke Connect - connect your remote modules in one location, then take your measurements up to 20 meters away with the Fluke 3000 FC multimeter. You'll be able to see the interaction between your remote test points on one single screen, in real time. You can even download the data to a PC for further analysis.

    Other capabilities of Fluke Connect and the 3000 FC Multimeter.

    • Add your laptop and go from logging to analysis and diagnosis.
    • Record over time using the Fluke Connect wireless modules and monitor circuit load changes for an hour, a shift or a week.
    • Use the Fluke Connect wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data.
    • Perform for analysis with your PC and share the results using Fluke Cloud™ storage and ShareLive™ video call. View data or graphs to get input from team members.

    Specifications

    AC Voltage
    Range¹ / resolution 600.0 mV / 0.1 mV
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy2 3 445 Hz to 500 Hz1.0% + 3
    500 Hz to 1 kHz2.0% + 3
    1. AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    mVRange / resolution600.0 mV / 0.1 mV
    Accuracy0.09% + 2
    VRange / resolution6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy0.09% + 2
    0.15% + 2
    )))Range / resolution600 Ω / 1 Ω
    AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    ΩRange / resolution600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy0.5% + 2
    0.5% + 1
    1.5% + 3
    Diode testRange / resolution2.000 V / 0.001 V
    Accuracy1% + 2
    µFRange / resolution1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF1 / 1 μF
    Accuracy1.2% + 2
    10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    mA AC
    (45 Hz to 1 kHz)
    Range1 / resolution60.00 mA / 0.01 mA
    400.0 mA/ 0.1 mA
    Accuracy1.5% + 3
    mA DC2Range1 / resolution60.00 mA / 0.01 mA
    400.0 mA3 / 0.1 mA
    Accuracy0.5% + 3
    1. All AC current ranges are specified from 5% of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range / resolution99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy10.1% + 1
    1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Overload protection1100 V RMS
    Input impedance (nominal)> 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection> 60 dB at 50 Hz or 60 Hz
    Overload protection1100 V RMS
    Input impedance (nominal)> 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 60 dB, DC to 60 Hz
    Normal mode rejection> 60 dB at 50 Hz or 60 Hz
    Overload protection1100 V RMS
    Input impedance (nominal)> 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection> 60 dB at 50 Hz or 60 Hz
    Open Circuit Test Voltage
    Overload protection1100 V RMS
    Input impedance (nominal)< 2.7 V DC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    < 0.7 V DC
    < 0.9 V DC
    Typical short circuit current< 350 mA
    Overload protection1100 V RMS
    Input impedance (nominal)< 2.7 V DC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    2.000 V DC
    Typical short circuit current< 1.1 mA
    mA Function
    Overload protectionFused, 44/100 A, 1000 V FAST Fuse
    Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functions± 12 counts for changes > 350 mS in duration.
    AC functions± 40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
    Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD)Update rate4/sec
    Volts, amps, ohms6000 counts
    Frequency10,000 counts
    Capacitance1,000 counts
    Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life250 hours minimum
    RF communications2.4 GHZ ISM Band
    RF communication rangeOpen air, unobstructedUp to 20m
    Obstructed, sheetrock wallUp to 6.5m
    Obstructed, concrete wall, or steel electrical enclosureUp to 3.5m
    TemperatureOperating-10°C to 50°C
    Storage-40°C to 60°C
    Temperature coefficient0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    AltitudeOperating2,000 m
    Storage12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326–1:2006, EN 61326–2–2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008
    FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
    Safety complianceANSI / ISA 61010–1 / (82.02.01): 3rd edition
    CAN / CSA-C22.2 No 61010-1-12: 3rd edition
    UL 61010–1: 3rd edition
    IEC / EN 61010–1:2010
    CertificationsCSA, FCC, CE
    Ingress Protection (IP) ratingIP54
    Pollution Degree2
    Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight340 g (12 oz)
    WarrantyThree years
    Not compatible with Fluke CNX test tools