Home / Testing Tools / FLUKE Wireless AC-DC Voltage Multimeter Kit FLUFLKV3003FCKIT

FLUKE Wireless AC-DC Voltage Multimeter Kit FLUFLKV3003FCKIT

Quantity
ADD TO CART
BUY IT NOW
  • Detail

    The FC Wireless v3003 AC-DC Voltage Measurement Kit is part of the Fluke Connect team of wireless test tools

    Connect the v3000 FC Wireless AC Voltage and v3001 FC Wireless DC Voltage Modules to your test points, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

    You'll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect® modules as a system for multiple measurements.

    From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless Voltage Modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

    Now you can take readings on moving machinery, with only the measurement module in harm's way.

    Detailed Specifications
    AC Voltage
    Range 1ResolutionAccuracy 2 3 4Accuracy 2 3 4
    45 Hz to 500 Hz500 Hz to 1 kHz
    600.0 mV0.1 mV1.0% + 32.0% + 3
    6.000 V0.001 V
    60.00 V0.01 V
    600.0 V0.1 V
    1000 V1 V
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of �� 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ��(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    FunctionRangeResolutionAccuracy
    mV600.0 mV0.1 mV0.09% + 2
    V6.000 V0.001 V0.09% + 2
    60.00 V0.01 V
    600.0 V0.1 V
    1000 V1 V0.15% + 2
    ��600 ��1 ��Meter beeps at < 25 ��, beeper detects opens or shorts of 250 ��s or longer.
    ��600.0 ��0.1 ��0.5% + 2
    6.000 k��0.001 k��0.5% + 1
    60.00 k��0.01 k��
    60.00 k��0.1 k��
    600.0 k��0.001 M��
    50.00 M��0.01 M��1.5% + 3
    Diode test2.000 V0.001 V1% + 2
    F1000 nF1 nF1.2% + 2
    10.00 ��F0.01 ��F
    100.0 ��F0.1 ��F
    9999 ��F11 ��F10% typical
    1. In the 9999 ��F range for measurements to 1000 ��F, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    FunctionRange 1ResolutionAccuracy
    mA AC
    (45 Hz to 1 kHz)
    60.00 mA0.01 mA1.5% + 3
    400.0 mA 30.1 mA
    mA DC 260.00 mA0.01 mA0.5% + 3
    400.0 mA 30.1 mA
    1. All AC current ranges are specified from 5% of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    RangeResolutionAccuracy 1
    99.99 Hz0.01 Hz0.1% + 1
    999.9 Hz0.1 Hz
    9.999 kHz0.001 kHz
    99.99 kHz0.01 kHz
    1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    FunctionOverload
    protection
    Input impedance
    (nominal)
    Common mode rejection ratio (1 k�� unbalance)Normal mode rejection
    1100 Vrms> 10 M�� < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
    1100 Vrms> 10 M�� < 100 pF> 60 dB, DC to 60 Hz 
    1100 Vrms> 10 M�� < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
    Open circuit test voltageFull scale voltageTypical short circuit current
    To 6 M��50 M��
    1100 Vrms< 2.7 VDC< 0.7 VDC< 0.9 VDC< 350 mA
    1100 Vrms< 2.7 VDC2.000 VDC< 1.1 mA
    mA Function
    Overload ProtectionFused, 44/100 A, 1000 V FAST Fuse
    Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functionsThe specified accuracy of the measurement function ��12 counts for changes > 350 mS in duration.
    AC functionsThe specified accuracy of the measurement function ��40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground1000 VDC or AC rms
    �� fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD)Update rate4/sec
    Volts, amps, ohms6000 counts
    Frequency10,000 counts
    Capacitance1,000 counts
    Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life250 hours minimum
    RF communications2.4 GHZ ISM Band
    RF communication rangeOpen air, unobstructedUp to 20 m
    Obstructed, sheetrock wallUp to 6.5 m
    Obstructed, concrete wall, or steel electrical enclosureUp to 3.5 m
    TemperatureOperating-10°C to 50°C
    Storage-40°C to 60°C
    Temperature coefficient0.1 x (specified accuracy) / °C (<18°C or >28°C)
    Relative humidity0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    AltitudeOperating2,000 m
    Storage12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety complianceANSI/ISA 61010-1 / (82.02.01)3rd edition
    CAN/CSA-C22.2 No 61010-1-123rd edition
    UL 61010-13rd edition
    IEC/EN 61010-12010
    CertificationsCSA, FCC, CE
    Ingress Protection (IP) ratingIP54
    Pollution degree2
    Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight340 g (12 oz)
    WarrantyThree years
    Not compatible with Fluke CNX test tools

     

    Fluke v3000 FC Wireless AC Voltage Module

    Accuracy is specified as ��([% of reading] + [number of least significant digits]). All ranges are autoranging.
    Accuracy is specified from 5% to 100% of the range obtained by autoranging, from 18°C to 28°C.

    Specifications
    Range / Resolution6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 2 3 445 Hz to 500 Hz1.0% + 3
    500 Hz to 1 kHz2.0% + 3
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of �� 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ��(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    General Specifications
    LCD w/ backlight3 digits, 6000 counts, updates 4/sec
    Battery type2 AA, NEDA 15 A, IEC LR6
    Battery life400 Hours
    MemoryRecord up to 65000 readings
    RF communications2.4 GHZ ISM Band
    RF communication rangeOpen air, unobstructedUp to 20 m
    Obstructed, sheetrock wallUp to 6.5 m
    Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
    Operating temperature-10°C to +50°C
    Storage temperature-40°C to +60°C
    Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Operating humidity90% at 35°C, 45% at 40°C, 45% at 50°C
    AltitudeOperating2,000 m
    Storage12,000 m
    EMCEN 61326-1:2006
    Safety complianceANSI/ISA 61010-1 / (82.02.01)3rd edition
    CAN/CSA-C22.2 No 61010-1-123rd edition
    UL 61010-13rd edition
    IEC/EN 61010-12010
    Safety ratingCAT IV 600 V, CAT III 1000 V
    CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) ratingIP42
    Pollution Degree2
    Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    Weight.22 kg (8 oz)
    WarrantyThree years
    Not compatible with Fluke CNX test tools

     

    Fluke v3001 FC Wireless DC Voltage Module

    Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ��([% of Reading ] + [Number of least significant digits]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18°C to 28°C.

    Voltage Specifications
    Function
    mVDCRange / Resolution600.0 mV / 0.1 mV
    Accuracy0.09% + 3
    VDCRange / Resolution6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy0.09% + 3
    Range / Resolution1000 V / 1 V
    Accuracy0.15% + 2
    General Specifications
    LCD w/ backlight3 digits, 6000 counts, 4/sec update rate
    Battery type2 AA Alkaline batteries, NEDA 15A, IEC LR6
    Log rate/intervalAdjustable by PC from 1 sec to 1 hr, default 1 min
    Battery life400 hours minimum
    MemoryRecord up to 65,000 readings
    RF communications2.4 GHz ISM Band
    RF communication rangeOpen air, unobstructedUp to 20 m
    Obstructed, sheetrock wallUp to 6.5 m
    Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
    Operating temperature-10°C to +50°C
    Storage temperature-40°C to +60°C
    Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity0% to 90% (0°C to 35°C), 0% to 75% (35°C to 40°C),
    0% to 45% (40°C to 50°C)
    EMCIEC 61236-1, Portable
    Safety complianceIEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2
    CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) ratingIP42
    Size (H x W x D)160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
    Weight0.255 kg (9 oz)
    WarrantyThree years
    Not compatible with Fluke CNX test tools
  • Customer Reviews