FLUKE Wireless AC-DC Voltage Multimeter Kit FLUFLKV3003FCKIT
Quantity
-
Detail
The FC Wireless v3003 AC-DC Voltage Measurement Kit is part of the Fluke Connect team of wireless test tools
Connect the v3000 FC Wireless AC Voltage and v3001 FC Wireless DC Voltage Modules to your test points, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.
You'll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect® modules as a system for multiple measurements.
From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless Voltage Modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.
Now you can take readings on moving machinery, with only the measurement module in harm's way.
Detailed Specifications AC Voltage Range 1 Resolution Accuracy 2 3 4 Accuracy 2 3 4 45 Hz to 500 Hz 500 Hz to 1 kHz 600.0 mV 0.1 mV 1.0% + 3 2.0% + 3 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of �� 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ��(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.DC Voltage, Continuity, Resistance, Diode Test and Capacitance Function Range Resolution Accuracy mV 600.0 mV 0.1 mV 0.09% + 2 V 6.000 V 0.001 V 0.09% + 2 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 0.15% + 2 �� 600 �� 1 �� Meter beeps at < 25 ��, beeper detects opens or shorts of 250 ��s or longer. �� 600.0 �� 0.1 �� 0.5% + 2 6.000 k�� 0.001 k�� 0.5% + 1 60.00 k�� 0.01 k�� 60.00 k�� 0.1 k�� 600.0 k�� 0.001 M�� 50.00 M�� 0.01 M�� 1.5% + 3 Diode test 2.000 V 0.001 V 1% + 2 F 1000 nF 1 nF 1.2% + 2 10.00 ��F 0.01 ��F 100.0 ��F 0.1 ��F 9999 ��F1 1 ��F 10% typical 1. In the 9999 ��F range for measurements to 1000 ��F, the measurement accuracy is 1.2% + 2. AC and DC Current Function Range 1 Resolution Accuracy mA AC
(45 Hz to 1 kHz)60.00 mA 0.01 mA 1.5% + 3 400.0 mA 3 0.1 mA mA DC 2 60.00 mA 0.01 mA 0.5% + 3 400.0 mA 3 0.1 mA 1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.Frequency Range Resolution Accuracy 1 99.99 Hz 0.01 Hz 0.1% + 1 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. Input Characteristics Function Overload
protectionInput impedance
(nominal)Common mode rejection ratio (1 k�� unbalance) Normal mode rejection 1100 Vrms > 10 M�� < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz 1100 Vrms > 10 M�� < 100 pF > 60 dB, DC to 60 Hz 1100 Vrms > 10 M�� < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz Open circuit test voltage Full scale voltage Typical short circuit current To 6 M�� 50 M�� 1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA 1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA mA Function Overload Protection Fused, 44/100 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum MIN/MAX Recording Accuracy DC functions The specified accuracy of the measurement function ��12 counts for changes > 350 mS in duration. AC functions The specified accuracy of the measurement function ��40 counts for changes > 900 mS in duration. General Specifications Maximum voltage between any terminal and earth ground 1000 VDC or AC rms �� fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate 4/sec Volts, amps, ohms 6000 counts Frequency 10,000 counts Capacitance 1,000 counts Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 250 hours minimum RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20 m Obstructed, sheetrock wall Up to 6.5 m Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m Temperature Operating -10°C to 50°C Storage -40°C to 60°C Temperature coefficient 0.1 x (specified accuracy) / °C (<18°C or >28°C) Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)Altitude Operating 2,000 m Storage 12,000 m Electromagnetic compatibility
EMI, RFI, EMC, RFEN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLESafety compliance ANSI/ISA 61010-1 / (82.02.01) 3rd edition CAN/CSA-C22.2 No 61010-1-12 3rd edition UL 61010-1 3rd edition IEC/EN 61010-1 2010 Certifications CSA, FCC, CE Ingress Protection (IP) rating IP54 Pollution degree 2 Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight 340 g (12 oz) Warranty Three years Not compatible with Fluke CNX test tools Fluke v3000 FC Wireless AC Voltage Module
Accuracy is specified as ��([% of reading] + [number of least significant digits]). All ranges are autoranging.
Accuracy is specified from 5% to 100% of the range obtained by autoranging, from 18°C to 28°C.Specifications Range / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 VAccuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 kHz 2.0% + 3 1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of �� 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ��(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.General Specifications LCD w/ backlight 3 digits, 6000 counts, updates 4/sec Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 400 Hours Memory Record up to 65000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20 m Obstructed, sheetrock wall Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C Altitude Operating 2,000 m Storage 12,000 m EMC EN 61326-1:2006 Safety compliance ANSI/ISA 61010-1 / (82.02.01) 3rd edition CAN/CSA-C22.2 No 61010-1-12 3rd edition UL 61010-1 3rd edition IEC/EN 61010-1 2010 Safety rating CAT IV 600 V, CAT III 1000 V Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Pollution Degree 2 Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) Weight .22 kg (8 oz) Warranty Three years Not compatible with Fluke CNX test tools Fluke v3001 FC Wireless DC Voltage Module
Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ��([% of Reading ] + [Number of least significant digits]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18°C to 28°C.
Voltage Specifications Function mVDC Range / Resolution 600.0 mV / 0.1 mV Accuracy 0.09% + 3 VDC Range / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 VAccuracy 0.09% + 3 Range / Resolution 1000 V / 1 V Accuracy 0.15% + 2 General Specifications LCD w/ backlight 3 digits, 6000 counts, 4/sec update rate Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6 Log rate/interval Adjustable by PC from 1 sec to 1 hr, default 1 min Battery life 400 hours minimum Memory Record up to 65,000 readings RF communications 2.4 GHz ISM Band RF communication range Open air, unobstructed Up to 20 m Obstructed, sheetrock wall Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) Relative humidity 0% to 90% (0°C to 35°C), 0% to 75% (35°C to 40°C),
0% to 45% (40°C to 50°C)EMC IEC 61236-1, Portable Safety compliance IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2 Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Size (H x W x D) 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in) Weight 0.255 kg (9 oz) Warranty Three years Not compatible with Fluke CNX test tools Customer ReviewsNo comments