FLUKE Milliamp Process Clamp Meter FLU772
FLUKE Milliamp Process Clamp Meter FLU772
Quantity
-
Detail
Fluke 772 Milliamp Clamp Meter measures, sources, and simulates 4-20 mA signals for testing control system I/O or IPs
The Fluke 772 adds to the basic capabilities of the Fluke 771 to save more time and expand its applications. With the 771, you'll also be able to: source and simulate 4-20 mA signals for testing control system I/O; measure 4-20 mA signals with in-circuit measurement; power a transmitter with the 24 V loop power supply; and automatically ramp and step change the 4-20 mA output for remote testing.
You'll be able to test 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down, which can save you time, and help you avoid possibly missing something going on in the process.
- Simulates 4-20 mA signals for testing control system I/O
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Measures 4 to 20 mA signals with in-circuit measurement
- Includes simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Features a detachable clamp with extension cable for measurements in tight locations
- Captures and displays changing measurements with Hold function
- Offers mA output linear ramp or 25% step output
- Extends battery life with auto-off and backlight timeout
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight to illuminate hard to see wires in dark enclosures
- Measures 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically changes the 4 to 20 mA output for remote testing
- Loop calibrator that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Simultaneously measures the mA signal with the clamp and sources a mA signal
- Delivers 0.01 mA resolution and sensitivity
- Measures mA signals for PLC and control system analog I/O
Specifications:
- Diameter of measurable conductor: 0.177” or 4.5 mm max
- Operating temperature: -10 to 50ºC
- Storage temperature: -25 to 60ºC
- Operating humidity: < 90% @ <30ºC, < 75% @ 30 to 55ºC
- Operating altitude: 0 to 2000 m
- IP rating: IP 40
- Vibration: Random 2 g, 5 to 500 Hz
- Shock: 1 meter drop test (except the jaw)
- EMI/RFI: Meets EN61326-1 | For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
- Temperature coefficient: 0.01% ºC, (< 18ºC or > 28ºC)
- Power, battery life: (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
- mA measurement (measured by clamp): Resolution / range: 0 to 20.99 mA | Accuracy: 0.2% + 5 counts | Resolution / range: 21.0mA to 100.0 mA | Accuracy: 1% + 5 counts
- mA measurement (measured in series with test jacks): Resolution / range: 0 to 24.00 mA | Accuracy: 0.2% + 2 counts
- mA source (maximum mA drive: 24 mA into 1,000 ohms): Resolution / range: 0 to 24.00 mA | Accuracy: 0.2% + 2 counts
- mA simulate (maximum voltage 50 V dc): Resolution / range: 0 to 24.00 mA | Accuracy: 0.2% + 2 counts
-